← back work · project
// bioclimatic design study

casa castillo.

a parasol over the house. labhaus studio designed a second roof above the first for the los santos sun, and we tested it: the house gains 450 cool hours a year, with no air-conditioning.

ai illustration of casa castillo, based on the 2020 study model: a long, low house on stilts under a thin flat roof, with louvered panels, on a grassy hillside among palms and trees

// ai illustration, based on the 2020 study model

location
los santos, panamá
year
2020
typology
residential
role
simulations + strategy validation
+450h
// the result

more cool hours a year, no air-conditioning.

simulated with the local climate before construction. design by labhaus studio, simulation by entrópica.

// the project

what was asked, and how it was solved.

// brief

casa castillo is a country house in los santos, in panamá's dry arc. labhaus studio designed it; we ran the simulations.

there the sun passes almost overhead, so the heat comes in through the roof. the design puts a second roof 30 cm above the first, like an umbrella.

// the answer

the second roof takes almost all the sun, and the roof of the house stops burning.

we also tested all 64 ways to close the patio with its panels. the best one lets in less than half the sun.

// key numbers

the study in six numbers.

valuewhat it means
74%of the direct sun on a flat roof comes from higher than 45°
−99%yearly sun on the main roof (1,900 to 16 kWh/m²)
−25 °Con the roof surface in its hottest hour (60.4 to 35.2 °C)
−5.5 °Con the ceiling at 3–4 pm, on the average day of the year
+450 hcomfortable hours a year (3,441 to 3,891), no air-conditioning
418–644 kWh/m²daytime sun on the patio, best to worst of 64 panel settings (868 with no panels)
// the study
01

the second roof makes the shade

section through the house and the patio. air moves between the two roofs; the sun does not, except early in the morning and late in the afternoon.

east-west section through the main house and the patio, cut elements hatched, with the house and the patio deck raised on 0.5 m stilts over a ventilated plenum. a detail of the west edge shows the slab roof, the parasol 0.30 m above it, the 1.00 m overhang, and a sun ray at 16.7°, the lowest sun that can reach the roof over the rooms.

hover or tap a part of the drawing

02

the roof of the house gets almost no sun

a year of sun on each surface, with the second roof lifted in the drawing to show the one below. the roof of the house goes from 1,900 to 16 kWh/m² a year.

exploded isometric of the house colored by yearly sun, from pale to dark red. the parasol, lifted above the house, is dark red (1,900 kWh/m²); the main roof under it is pale (16 kWh/m²). walls and patio are in between.

hover or tap a part of the drawing

03

450 more cool hours a year

every hour of the year inside the house, with no air-conditioning. with the parasol the afternoons heat up less: from 3,441 to 3,891 comfortable hours a year.

loading 8,760 hours…
by month
by hour of day
became comfortablebecame too coolbecame too warmunchanged: comfortableunchanged: too warmunchanged: too cool
04

a patio set to the sun

we tested all 64 ways to close the patio with its six panels. the best lets in 418 kWh/m² of daytime sun a year, less than half the patio with no panels (868). the 2020 setting lets in 479.

loading 64 settings…
↓ house side
all 64 settings, least sun to most
daytime sun on the patio, kWh/m² a year
20040080012001600
// method and data

how we got the numbers.

  • climate: santiago de veraguas (cantú airport) tmyx weather file, the closest station to the site. site 7.80 n, 80.57 w.
  • model: the main house (6.1 × 19.1 m) and the pool house, free-running with natural ventilation, simulated in energyplus through honeybee for grasshopper.
  • design case: the same house with a second roof 0.30 m above the slab roof and its 1 m overhang. in both cases the house and the patio deck stand on 0.5 m stilts, and the house floor is open to the outdoor air. the 2020 design model also draws the air under the house as a ventilated plenum zone; a 2026 test run without that zone changes the house results by 0.1 °C at most, so the gains come from the parasol.
  • comfort: ashrae 55 adaptive model, 90% acceptability band, still air. with the weather-file wind as air speed, as in the delivered study, the gain is 4,296 to 4,930 h.
  • sun on surfaces and on the patio: cumulative sky (tregenza patches, direct sun binned per patch, isotropic diffuse, 0.2 ground reflectance) and ray casting on 0.5 m grids. patio at 0.9 m, 07–18 h.
  • drawings: rhino make2d lines of the 2020 model; colors computed on the same geometry and view.
  • check: in 2026 we reran the archived 2020 energyplus models (9.1) to recover the hourly results shown here.

design: labhaus studio. study and graphics: entrópica. tools: energyplus, ladybug tools (honeybee, ladybug), rhino, python.