← back work · project
// academic work

new chautauqua institute.

a facade that reads the city's shadow. in singapore the neighbors shade the lower floors, so the louvers tighten as the building rises. the sun on the glass drops by 71%.

ai visualization loosely based on the new chautauqua institute: a mid-rise building wrapped in horizontal timber louvers, with planted terraces and roof solar panels, on a tree-lined street in singapore

// ai visualization, loosely based on the 2017 studio project

location
singapore
year
2017
typology
mixed-use
status
academic project
role
team project, upenn arch 708
josé barría, bhakti kothari, neeharika siram
−71%
// the result

sun on the glass behind the louvers, in a year.

academic team project, university of pennsylvania, 2017. models rerun in 2026. the image is an ai visualization.

// the project

what was asked, and how it was solved.

// brief

the new chautauqua institute is a 2017 studio project at the university of pennsylvania, by josé barría, bhakti kothari and neeharika siram: a research and residence building in central singapore.

this page follows one idea from an early version of the design. in 2026 the models were rerun.

// the answer

the top floor, above the neighbors' roofs, gets 2.9 times more sun than the first. so the louvers are not spread evenly: 7 on the first floor and 14 on the top.

// key numbers

the study in six numbers.

valuewhat it means
93%of the hours of the year in heat stress, even in the shade (utci 26 °C or above)
35 → 74%comfortable hours in one office room: shades, better glass, natural ventilation
2.9×more sun on the top floor's glass than on the first, before any shading
7 to 14louvers per floor, from the first floor to the top
−71%sun on the glass behind the louvers (389 to 114 kWh/m² a year)
94%of the floor area with enough daylight (sDA) behind the louvers
// the study
01

the city shades the bottom, the sky burns the top

a year of sun on the glass of each floor, with no louvers. the first floor gets 208 kWh/m²; the top floor, above the neighbors, 603.

sun on the glass, no louvers (kWh/m² a year)floor
floorno louvers
floor 1208.2 kWh/m²
floor 2271.0 kWh/m²
floor 3360.9 kWh/m²
floor 4502.6 kWh/m²
floor 5602.6 kWh/m²
02

louvers that tighten with height

how many louvers each floor gets, as drawn in 2017 and spread by the sun. they are very close. one more sits below the first floor: 50 in all.

as drawn in 2017in proportion to the sun
louvers per floor
as drawn in 2017in proportion to the sun
floor 1208 kWh/m² 75
one more louver sits below the first floor: 50 in all
floor 2271 kWh/m² 77
floor 3361 kWh/m² 109
floor 4503 kWh/m² 1113
floor 5603 kWh/m² 1415
03

same louvers, placed by the sun

the same 50 louvers, spaced as in 2017 or evenly. the 2017 spacing takes 17% of the sun off the top floor and leaves more light below, where the city already gives shade.

even spacing2017 spacing
sun on the glass behind the louvers (kWh/m² a year)floor
flooreven spacing2017 spacing
floor 124.7 kWh/m²62.2 kWh/m²
floor 241.4 kWh/m²69.3 kWh/m²
floor 370.7 kWh/m²103.6 kWh/m²
floor 4139.0 kWh/m²151.5 kWh/m²
floor 5220.6 kWh/m²182.6 kWh/m²
04

less glare, almost the same light

daylight on each floor. with the 2017 louvers, 94% of the floor has enough light (99% with no louvers), and the over-lit hours on the top floor drop from 37% to 10%.

no louvers2017 louverseven louvers
floor area with enough daylight, sDA (%)
no louvers2017 louverseven louvers
floor 1 97%82%75%
over-lit hours: 13.7% no louvers · 5.5% 2017 · 0.5% even
floor 2 99%89%85%
over-lit hours: 17.0% no louvers · 4.6% 2017 · 1.2% even
floor 3 100%99%99%
over-lit hours: 22.1% no louvers · 7.3% 2017 · 3.5% even
floor 4 100%100%100%
over-lit hours: 30.9% no louvers · 12.2% 2017 · 9.3% even
floor 5 100%100%100%
over-lit hours: 36.7% no louvers · 9.9% 2017 · 17.6% even
// method and data

how we got the numbers.

  • climate: singapore iwec weather file (changi, 1.37° n). utci in the shade with mean radiant temperature equal to air temperature; heat stress = utci 26 °C or above.
  • office room ladder: the archived 2017 energyplus room (7 × 12 × 4 m, south glass, free-running), rerun in energyplus 9.1 for all 8,760 hours; adaptive comfort (ashrae 55, 90%), still air. the 2017 boards used the weather-file wind indoors and one june week, so they read differently. better glass: ashrae 189.1 zone 1 values (assumed).
  • building: an early 2017 version of the design, a 25.0 × 51.5 m box of five floors above an open ground floor, wrapped in 50 horizontal louvers 0.30 m deep (49 on floors 1 to 5, one below the first floor), on the 2017 site model with its neighbors. glass assumed full height at the inner face of the columns.
  • sun on the glass: radiance (rcontrib), cumulative perez sky in 145 patches from the weather file, context included, no ground reflection. the even case moves the same 50 louvers to equal spacing.
  • daylight: radiance two-phase daylight coefficients (577-patch sky, 6 bounces), work plane 0.75 m on a 1.5 m grid, 8-18 h. sDA = share of floor area with 300 lx or more half of the hours. over-lit = above 3,000 lx. assumed: glass visible transmittance 0.60, open floors with no core, reflectances 0.2 floor, 0.5 walls, 0.8 ceiling.
  • north: as in the 2017 site model; the real lot runs about n30e.

team: josé barría, bhakti kothari, neeharika siram. critics: william braham, mostapha sadeghipour roudsari. arch 708 environmental building design studio, university of pennsylvania, spring 2017. 2026 rerun and graphics: josé barría. an academic project, not an entrópica commission. the hero image is an ai visualization.